The Panasonic DP-102-E-P Digital Pressure Sensor is a gauge pressure sensor designed for high-performance pressure monitoring in non-corrosive gas systems. This sensor features a rated pressure range of -0.100 to +1.000 MPa, and a set pressure range of -0.101 to +1.010 MPa, providing accurate and reliable pressure readings in a wide range of applications. Its versatility in pressure monitoring is enhanced by analog outputs, including voltage (0.6 to 5 V) and current (2.4 to 20 mA), as well as comparative output with selectable output modes like NO/NC, EASY, Hysteresis, and Window comparator modes.
The Panasonic DP-102-E-P Digital Pressure Sensor features a 4-digit LCD display with a 3-color indicator to offer clear pressure status, and its response time can be customized between 2.5 ms to 5,000 ms. For efficient power consumption, the DP-102-E-P operates in normal and ECO modes, providing flexibility in energy usage.
Built to endure harsh industrial environments, this sensor is IP40 rated, resistant to vibration (10 to 500 Hz), and shock-resistant up to 100 m/s². It is also engineered to withstand high pressure, with a pressure withstand ability of 1.5 MPa. This model is ideal for pressure monitoring in a wide variety of industrial, pneumatic, and gas applications.
| Brand | Panasonic |
| Product Number | DP-102-E-P |
| Part Number | UDP102EP |
| CE Marking Directive Compliance | EMC Directive, RoHS Directive |
| Type of Pressure | Gauge pressure |
| Rated Pressure Range | -0.100 to +1.000 MPa |
| Set Pressure Range | -0.101 to +1.010 MPa -101 to +1,010 kPa -1.03 to +10.30 kgf/cm2 -1.01 to +10.10 bar -14.6 to +146.4 psi |
| Pressure Withstand ability | 1.5 MPa |
| Applicable Fluid | Non-corrosive gas |
| Supply Voltage | 12 to 24 V DC ±10 % Ripple P-P 10 % or less |
| Power Consumption | Normal operation : 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage) ECO mode : 480 mW or less at STD (Current consumption 20 mA or less at 24 V supply voltage) 360 mW or less at FULL (Current consumption 15 mA or less at 24 V supply voltage) |
| Comparative Output | PNP open-collector transistor - Maximum source current : 100 mA - Applied voltage : 30 V DC or less (between comparative output and +V) - Residual voltage : 2 V or less (at 100 mA source current) |
| Comparative Output: Output Operation | NO / NC (selectable by key operation) |
| Comparative Output: Output Modes | EASY mode / Hysteresis mode / Window comparator mode |
| Comparative output: Hysteresis | Minimum 1 digit (variable)(however, 2 digits when using psi unit) |
| Comparative Output: Repeatability | ±0.2 % F.S. (within ±2 digits) |
| Comparative Output: Response Time | 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation |
| Comparative Output: Short-Circuit Protection | Incorporated |
| External Input | - |
| Analog Current Output | - |
| Analog Voltage Output | - |
| Display | 4 digits + 4 digits 3-color LCD display (Display refresh rate : 250 ms, 500 ms, 1,000 ms, selectable by key operation) |
| Display: Displayable Pressure Range | -0.101 to +1.010 MPa -101 to +1,010 kPa -1.03 to +10.30 kgf/cm2 -1.01 to +10.10 bar -14.6 to +146.4 psi |
| Indicator | Orange LED (Comparative output 1 operation indicator, comparative output 2 operation indicator : Lights up when each comparative output is ON) |
| Protection | IP40 (IEC) |
| Ambient Temperature | -10 to +50 ℃ +14 to +122 ℉, Storage : -10 to +60 ℃ +14 to +140 ℉ |
| Ambient Humidity | 35 to 85 % RH (No dew condensation or icing allowed), Storage : 35 to 85 % RH |
| Voltage Withstand ability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Insulation Resistance | 50MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure |
| Vibration Resistance | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each (when panel is mounted: 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each) |
| Shock Resistance | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each |
| Temperature Characteristics | Within ±1 % F.S. (at +20 ℃ +68 ℉) |
| Pressure Port | M5 female thread + G 1/8 male thread |
| Material | Enclosure : PBT (glass fiber reinforced), LCD display : Acrylic, Pressure port : Stainless steel (SUS303), Mounting threaded part : Brass (nickel plated), Switch part : Silicone rubber |
| Connecting Method | Connector |
| Cable Length | Total length up to 100 m 328.084 ft (less than 30 m 98.425 ft when conforming to CE marking) is possible with 0.3 mm2, or more, cable |
Note : All tax and custom duty should be pay by buyer only.
Note: All trademarks and trade names used are the property of their respective owners.
Ships within 48 hours · Estimated delivery Jul 11 - Jul 16
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order