20% OFF shipping at neumaticosmexico.com on orders over $79 + up to 10% OFF products
neumaticosmexico.com
home > RANSBURG 80120-611 External Cascade 9060 (Domestic) > RANSBURG 80120-611 External Cascade 9060 (Domestic)
download picture
RANSBURG 80120-611 External Cascade 9060 (Domestic)RANSBURG 80120 611 ASSY, EXTERNAL CASCADE 9060, DOMESTIC The Ransburg 9060 Cascade Low Voltage Controller(80120 XXX) is used to provide high voltage for electrostatic application equipment. It uses a combination of proven high voltage generation technology and microprocessor based control. It uses a variable voltage output to drive an external cascade that amplifies the voltage to a high kV level. It also uses current feedback information to maintain
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

RANSBURG 80120-611 ASSY, EXTERNAL CASCADE 9060, DOMESTIC

The Ransburg 9060 Cascade Low Voltage Controller(80120-XXX) is used to provide high voltage for electrostatic application equipment. It uses a combination of proven high voltage generation technology and microprocessor-based control. It uses a variable voltage output to drive an external cascade that amplifies the voltage to a high kV level. It also uses current feedback information to maintain the desired set point. The processor circuitry provides the maximum in applicator transfer efficiency, while maintaining the maximum safety.

The 9060 Controller can operate in either LOCAL mode or REMOTE mode conditions. In the LOCAL mode, the selection and adjustment of set point values is performed from the controller front panel. The triggering of the HV in LOCAL mode is initiated by the optional airflow switch built into the controller (which senses airflow triggered by a standard handgun) or via a single discrete remote I/O trigger
signal. In REMOTE mode, the selection and adjustment of the set point can be performed using either discrete or analog remote I/O signals. Two tripleset signals are provided that can be used to select one of the same three presets that are set and used in LOCAL mode. Two analog remote I/O set point signals are provided, one for current and one for voltage, and can be used to control the set point (See the Operation portion of this Manual for more information). The REMOTE mode triggering of HV is performed using a single discrete remote I/O trigger signal.

SAFETY FEATURES
When used with the appropriate applicators and cascades, the Ransburg 9060 Cascade Low Voltage Controller provides maximized operational safety. The protections include detection of Boot Faults, Ground Faults, Cable Faults, Feedback Signal Faults, Overvoltage, and Overcurrent. The microprocessor circuits provide a controlled output load curve, which limits the high voltage output to safe levels while monitoring control and feedback signals for unsafe conditions. Maximum operational safety is obtained when the correct applicator settings are used and when safe distances between the applicator and target are observed and followed. The maximum efficiency of the low voltage controller is based on load.

 

 

9060 Controller Features
1 kV Display
2 Micro Amp Display
3 High Voltage on Indicator
4 Unit ON - OFF Switch
5 Set Point Adjust Buttons
6 Fault Indicator
7 Reset Button
8 Standard I/O Connector
9 Fuses
10 Low Voltage Cable Connector
11 AC Inlet Receptacle
12 Ground Wire Assembly & Lug
13
Air Flow Switch Connectors (Optional)
14 Interlock I/O Connector
Technical Specifications
Model Selection Ransflex Automatic Solvent
Plug Selection Domestic 
Environmental
Operating Temperature: 0°C to +40°C
Storage and Shipping Temperature:
-40°C to +85°C (Allow power supply to go to room temperature before use)
Humidity: 95% Non-Condensing
Physical
Height: 14.0 cm (5.5 inches)
Width: 21.6 cm (8.5 inches)
Depth: 19.1 cm (7.5 inches)
Weight: 3.4 kg (7.5 lbs.)
Electrical
Input Voltage: 100-240 VAC
Frequency: 50 or 60 Hz
Current: 1 A max. RMS
Wattage: 40 watts (max.)
Output Voltage: 20-VDC (max.)
Output Current: 1A DC (max.)
Ground: Use known good earth ground

RANSBURG 80120-611 External Cascade 9060 (Domestic)

Item no : 18282112199
sold recently : Login >>
US$ 2754.00
Pay in 4 interest-free payments of $688.50 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 11 - Jul 16

Enjoy 20% off shipping

US$ 2754.00

1-11

US$ 2478.60

12-35

US$ 1927.80

36-59

US$ 1652.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches