20% OFF shipping at neumaticosmexico.com on orders over $79 + up to 10% OFF products
neumaticosmexico.com
home > 1771-P6R Allen-Bradley Series Power Supply Module Datasheet & Technical Manual > 1771-P6R Allen-Bradley Series Power Supply Module Datasheet & Technical Manual
download picture
1771-P6R Allen-Bradley Series Power Supply Module Datasheet & Technical ManualHIMA H4135A HIMatrix Safety Systems The HIMA H4135A, also cataloged as the H4135A Safety Related Relay Module, operates as a dedicated hardware component for safety related circuits within HIMatrix Safety Systems platforms. Hardware Specifications Parameter Specification Model H4135A Brand HIMA Origin Germany Module Type Safety Related Relay Module (Relay Amplifier) Input Rating 24 VDC ( 15% to +20%), 40 mA maximum Output Type Floating NO (Normally
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

HIMA H4135A HIMatrix Safety Systems

The HIMA H4135A, also cataloged as the H4135A Safety-Related Relay Module, operates as a dedicated hardware component for safety-related circuits within HIMatrix Safety Systems platforms.

Hardware Specifications

Parameter Specification
Model H4135A
Brand HIMA
Origin Germany
Module Type Safety-Related Relay Module (Relay Amplifier)
Input Rating 24 VDC (-15% to +20%), 40 mA maximum
Output Type Floating NO (Normally Open) contact
Switching Time 8 ms
Reset Time 6 ms
Wire Cross-Section 2.5 mm2 (AWG 14) maximum connecting wires
System Compliance RC1 to RC6 according to DIN V 19250 / 01.89
Operating Temp -25 to +60 deg C
Protection Class IP20 according to DIN 40050
Power Consumption 1 W typical
Dimensions 70.5 x 80 x 20 mm
Weight 0.08 kg

SIL3 Certification and Fail-Safe State Execution

The H4135A satisfies strict requirement criteria for functional safety, securing an infrastructure path capable of SIL3 certification and fail-safe state execution. Operating as a hardware-based relay amplifier, the module enforces a de-energize-to-trip safety standard to handle interlock signals up to Requirement Class RC1...RC6 parameters. Integrated galvanic isolation separates the low-current logic input boundary from the floating NO field contacts, restricting transient faults and validating localized safety instrumented loop execution under critical shutdown criteria.

Frequently Asked Questions

Q: What physical state do the output contacts assume when control input power to the H4135A is removed?

A: The module executes a de-energize-to-trip sequence, causing the floating NO (Normally Open) contacts to automatically drop open and isolate the connected field loops.

Q: Is structural performance affected if the module is mounted vertically rather than horizontally?

A: No. The physical construction allows horizontal or vertical installation layout orientations on standard DIN rails without modifying execution timing or requiring thermal assembly margins.

Q: Can this unit handle high-vibration field applications without terminal degradation?

A: Yes, provided the wiring terminations use the maximum wire cross-section up to 2.5 mm2 (AWG 14) and are secured to prevent mechanical tension across the internal relay casing boundaries.

Field Installation Guidelines

  • Mounting Rail Stability: Fix the compact terminal enclosure onto a standard top-hat DIN rail (DIN 32 mm) or C-profile. Ensure the locking tabs engage the rail securely to avoid structural dislodgement.
  • Terminal Wiring Constraints: Terminate all connections using stranded copper wire with a maximum cross-section of 2.5 mm2 (AWG 14). Strip insulation uniformly to avoid exposed conductor segments.
  • Contact Shielding Protocols: Route the 24 VDC inductive coil power loops in a discrete pathway isolated from data communication cables to mitigate electromagnetic induction.
  • Environmental Enclosure Limits: Mount the IP20 housing inside a dust-free and moisture-controlled industrial electrical panel to preserve operations across the -25 to +60 deg C temperature span.

1771-P6R Allen-Bradley Series Power Supply Module Datasheet & Technical Manual

Item no : 99844566708
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 18 - Jul 23

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches