20% OFF shipping at neumaticosmexico.com on orders over $79 + up to 10% OFF products
neumaticosmexico.com
home > Genuine Woodward 5437-080 Netcon Terminal Block Interface > Genuine Woodward 5437-080 Netcon Terminal Block Interface
download picture
Genuine Woodward 5437-080 Netcon Terminal Block InterfaceProduct Details Product Overview The Woodward 5437 080 serves as a specialized Netcon Field Terminal Relay Module within the globally recognized MicroNet control architecture. Engineered for high speed signal conditioning in turbine and engine applications, this module facilitates precise communication between field devices and the central control platform. It utilizes a standardized 37 pin connector to ensure secure, high density wiring
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Product Details

Product Overview

The Woodward 5437-080 serves as a specialized Netcon Field Terminal Relay Module within the globally recognized MicroNet control architecture. Engineered for high-speed signal conditioning in turbine and engine applications, this module facilitates precise communication between field devices and the central control platform. It utilizes a standardized 37-pin connector to ensure secure, high-density wiring configurations. We provide this unit as 100% Brand New original stock, ensuring it meets the rigorous demands of power generation, marine propulsion, and heavy industrial automation.

Technical Specifications

The 5437-080 integrates rugged hardware with precise electrical switching capabilities.

Parameter Specification
Catalog Number 5437-080
Manufacturer Woodward
Series MicroNet / Netcon
Product Type Relay Module / Field Terminal Block
Connector Type 37-Pin D-Sub Connector
Isolation Galvanic Isolation for Noise Immunity
Operating Temperature 0°C to +60°C
Weight 0.46 lbs (0.21 kg)
Dimensions 170 × 100 × 50 mm
Mounting Rack or Slot Compatible
Compliance CE, UL Certified

Engineering Advantages

  • Galvanic Noise Rejection: The module incorporates high-level galvanic isolation. This shielding prevents electromagnetic interference (EMI) and ground loops from disrupting the sensitive microprocessor logic of the MicroNet bus, maintaining system stability in electrically "noisy" power plant environments.

  • Simplified Wiring Architecture: The 37-pin block connection allows for centralized field wiring. By consolidating relay outputs into a single high-density interface, the module reduces cabinet clutter and significantly shortens the time required for loop checks and troubleshooting.

  • Optimized for High-Availability: Woodward designed the 5437-080 for continuous operation in mission-critical systems. The relay contacts provide dependable actuation for solenoids and fuel valves, where millisecond timing directly impacts engine performance and safety.

  • Rugged Industrial Durability: The hardware withstands the mechanical stress of marine and industrial vibrations. Even in extreme environments, the module maintains electrical continuity across its 37 pins, preventing intermittent signal loss during heavy engine cycling.

FAQs

Q: Does the 5437-080 replace the 5437-053 or 054 models directly?

A: While they belong to the same MicroNet family, the 5437-080 is specifically a Netcon-series field terminal. You must verify the specific relay logic and pinout mapping in your GAP (Graphical Application Programmer) software or system manual before substituting, as I/O channel assignments often vary between sub-models.

Q: What is the benefit of the 37-pin connector over individual terminal strips?

A: The 37-pin interface enables "Plug-and-Play" replacement of the control module without rewiring individual field wires. This minimizes human error during maintenance and drastically reduces MTTR (Mean Time To Repair).

Q: Are these units tested before shipping?

A: We supply the Woodward 5437-080 in 100% Brand New condition. Every unit passes factory-grade quality control inspections to ensure that each of the 37 connection points and internal relays operates according to original Woodward specifications.

Q: Can this module handle inductive loads?

A: Yes, the integrated relays are designed for industrial switching; however, we recommend external surge suppression for highly inductive loads (like large solenoids) to maximize the lifespan of the internal relay contacts.

Genuine Woodward 5437-080 Netcon Terminal Block Interface

Item no : 95634637861
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 14 - Jul 19

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches