Shopping security
The HIMA H4135, also cataloged as the H4135 Safety Relay Module, operates as a dedicated hardware component for fail-safe logic processing within HIMatrix programmable safety systems.
| Parameter | Specification |
|---|---|
| Model | H4135 |
| Brand | HIMA |
| Origin | Germany |
| Module Type | Safety Logic Solver / Safety Controller Module |
| Safety Certification | IEC 61508 SIL 3, IEC 61511 SIL 3, PL e (ISO 13849-1) |
| Digital Inputs | 16 fail-safe, 24 VDC, type 3 |
| Digital Outputs | 12 fail-safe, 24 VDC, 0.5 A, short-circuit proof |
| Analog Inputs | 4 channels, 4-20 mA or 0-10 V, 12-bit resolution |
| Communication Ports | 2x Ethernet, RS-485, CAN, optional PROFIBUS DP |
| Power Supply | 24 VDC +/-20% |
| Power Consumption | 15 W typical |
| Operating Temp | -20 to +70 deg C |
| Protection Class | IP20 |
| Dimensions | Standard DIN-rail mountable footprint |
| Weight | 2.0 kg (Shipping Weight) |
The H4135 is cross-examined and validated under IEC 61508 protocols to maintain SIL3 certification constraints across high-integrity hardware paths. Internal architecture executes ongoing internal diagnostics with a cycle time of 10 ms or greater, ensuring that any internal hardware malfunction triggers immediate fail-safe state execution to isolate field-side loops. De-energize-to-trip mechanisms operate alongside triple modular redundancy (TMR) 2oo3 architecture options or 2oo2D internal structures to prevent latent diagnostic blind spots while enforcing electrical galvanic isolation across all logic-solving elements.
Q: What action does the H4135 output circuit execute during an overcurrent event on a digital channel?
A: The 12 fail-safe digital outputs are short-circuit proof. When an overcurrent condition surpasses the 0.5 A channel threshold, internal safety switches isolate the line to enforce a fail-safe state.
Q: Is hot-swapping supported for the H4135 module on the DIN rail during active operations?
A: No. Modifying physical terminations or extracting the H4135 safety controller module while the 24 VDC power supply line is energized can induce diagnostic faults and interrupt the safety instrumented loop.
Q: What protocols are supported natively on the integrated Ethernet ports for safety interlocking?
A: The dual Ethernet ports support HIMA Safe Ethernet (HSE) for safe inter-module communications, alongside standard industrial protocols including Modbus TCP and PROFINET.
Ships within 48 hours · Estimated delivery Jul 18 - Jul 23