home > DeltaV S-Series KJ3241X1-BK1 12P4710X082 Interface > DeltaV S-Series KJ3241X1-BK1 12P4710X082 Interface
download picture
DeltaV S-Series KJ3241X1-BK1 12P4710X082 InterfaceProduct Overview The Emerson KJ3241X1 BK1 (Assembly SE4006P2 12P4710X082) functions as a high performance Serial Interface Module designed for the DeltaV S Series Distributed Control System (DCS). This module enables seamless data integration between the DeltaV controller and external third party devices, such as Motor Control Centers (MCCs), PLCs, weigh scales, and analyzers. By supporting standard industrial protocols like Modbus RTU, the KJ3241X1
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Product Overview

The Emerson KJ3241X1-BK1 (Assembly SE4006P2 / 12P4710X082) functions as a high-performance Serial Interface Module designed for the DeltaV™ S-Series Distributed Control System (DCS). This module enables seamless data integration between the DeltaV controller and external third-party devices, such as Motor Control Centers (MCCs), PLCs, weigh scales, and analyzers. By supporting standard industrial protocols like Modbus RTU, the KJ3241X1-BK1 bridges the gap between specialized field hardware and the central control strategy. We supply this module as 100% Brand New original hardware, ensuring deterministic communication and high-speed data throughput for your automated facility.

Part Number Breakdown

  • KJ3241X1-BK1: Primary S-Series hardware identifier for the Serial Interface Card.

  • SE4006P2: Emerson system part number for the Serial Interface.

  • 12P4710X082: Internal manufacturing reference and revision number.

Technical Specifications

Feature Details
Manufacturer Emerson (USA)
Model Number KJ3241X1-BK1
Series DeltaV™ S-Series
Module Type Serial Interface Card
Interface Protocols RS232, RS422/485, Modbus RTU
Baud Rate Configurable up to 115.2 Kbps
Isolation Port-to-System Galvanic Isolation
Diagnostics Communication link status and card health LEDs
Power Supply 24 VDC Nominal via Carrier
Dimensions 4.4 cm x 10.2 cm x 10.8 cm
Weight 0.2 kg
Operating Temp -20 °C to +60 °C

Engineering Advantages

  • Universal Third-Party Integration: The KJ3241X1-BK1 eliminates the need for complex gateway hardware. It allows the DeltaV system to read and write data directly to any device supporting RS232 or RS485 protocols. This simplifies the network architecture and reduces the overall cost of multi-vendor system integration.

  • Deterministic Data Acquisition: The module offloads serial processing from the main controller CPU. This dedicated processing ensures that high-speed serial traffic does not impact the execution timing of critical PID loops or safety logic within the DeltaV environment.

  • Robust Signal Isolation: Integrated galvanic isolation protects the DeltaV backplane from electrical noise and ground loops common in long-distance serial runs. This hardware barrier prevents transients from external devices from damaging the central DCS components.

  • Advanced Error Mapping: The module continuously monitors the integrity of the serial link. It identifies parity errors, framing errors, and timeout conditions, providing detailed diagnostic information to the DeltaV operator station for rapid troubleshooting of field-side communication issues.

  • Hot-Swap Maintenance Support: Designed for continuous operation, the KJ3241X1-BK1 supports hot-swapping. Maintenance personnel can replace a module without powering down the carrier, ensuring that adjacent I/O cards and system segments remain fully operational during servicing.

FAQs

  • Does the KJ3241X1-BK1 support both RS232 and RS485?

    Yes. You can software-configure the ports for RS232, RS422, or RS485 (2-wire or 4-wire) communication. This versatility allows a single spare part to support various field device interfaces across your plant.

  • Which DeltaV software license is required for this module?

    Integrating serial data usually requires a Serial Dataset license within the DeltaV system. Ensure your system license count covers the additional datasets generated by the KJ3241X1-BK1 to enable full data visibility.

  • What is the maximum distance for the RS485 interface?

    The RS485 interface typically supports distances up to 1,200 meters (4,000 feet) without a repeater, depending on the baud rate and cable quality. For longer runs or high-noise environments, we recommend using shielded twisted pair cabling.

DeltaV S-Series KJ3241X1-BK1 12P4710X082 Interface

Item no : 24167931802
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 14 - Jul 19

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches