Shopping security
The Wilkins 12-ZW1070XLCPVC is an Aqua-Gard® thermostatic mixing valve designed for point-of-use scald protection with 1/2" CPVC connections for residential and commercial applications.
Key Specifications:
Other Related Variants:
Materials:
The Zurn 12-ZW1070XLCPVC is designed to be installed at the point of use for individual outlets and single-use applications including plumbing fixtures, appliances, sinks, lavatories, bathtubs, and sensor faucets where final control of water temperature is required.
ASSE Listed 1070; cUPC Listed; CSA Certified B125.70; NSF/ANSI/CAN 61-9 Q≤1
Features & Benefits:
Q: What is the maximum pressure differential between hot and cold inlets?
A: The maximum pressure differential is 15 psi between hot and cold inlets for proper operation.
Q: What temperature ranges are required for hot and cold supply water?
A: Hot supply should be 120-195°F maximum and cold supply should be 39-80°F for the Wilkins 12-ZW1070XLCPVC to function properly.
Q: Does the outlet temperature need to be field adjusted?
A: Yes, the temperature must be field set within the 95-115°F outlet temperature range with +/- 3°F accuracy.
NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.